| Measurement (U.S. Customary
Units) |
| Direct Transmission Density (6") |
15
sec. |
1 min. |
4 min. |
| Precision at 120 pcf |
±0.42 pcf |
±0.21 pcf |
±0.11 pcf |
Composition error at 120 pcf
|
±1.25 pcf |
±1.25 pcf |
±1.25 pcf |
| Surface error (0.05", 100% Void) |
-1.1 pcf |
-1.1 pcf |
-1.1 pcf |
|
|
| Backscatter (98%) (4") |
15
sec. |
1 min. |
4 min. |
| Precision at 120 pcf |
±1.00 pcf |
±0.50 pcf |
±0.25 pcf |
| Composition error at 120 pcf |
±2.50
pcf |
±2.50
pcf |
±2.50
pcf |
| Surface error (0.05", 100% Void) |
-4.7
pcf |
-4.7
pcf |
-4.7
pcf |
|
|
| Moisture at 15 pcf |
15 sec. |
1 min. |
4 min. |
| Precision at 15 pcf |
±0.64
pcf |
±0.32
pcf |
±0.16
pcf |
Surface error (0.05", 100% Void)
Depth of measurement @ 15
pcf (8.45") |
-1.12 pcf
|
-1.12 pcf
|
-1.12 pcf
|
| |
| Measurement (S.I. Units) |
| Direct Transmission Density-150mm |
15
sec. |
1 min. |
4 min. |
| Precision at 2000 kg/m3 |
±6.8 kg/m3
|
±3.4 kg/m3 |
±1.7 kg/m3 |
Composition error at 2000 kg/m3
|
±20.0 kg/m3
|
±20.0 kg/m3 |
±20.0 kg/m3 |
Surface error (1.25mm, 100% Void)
|
-17.0 kg/m3 |
-17.0 kg/m3 |
-17.0 kg/m3 |
|
|
| Backscatter (98%) (100mm) |
15
sec. |
1 min. |
4 min. |
| Precision at 2000 kg/m3 |
±16.0 kg/m3 |
±8.0 kg/m3 |
±4.0 kg/m3 |
| Composition error at 2000 kg/m3 |
±40.0
kg/m3 |
±40.0
kg/m3 |
±40.0
kg/m3 |
| Surface error (1.25mm, 100% Void) |
-75.0 kg/m3 |
-75.0 kg/m3 |
-75.0 kg/m3 |
|
|
| Moisture |
15 sec. |
1 min. |
4 min. |
| Precision at 250 kg/m3 |
±10.3
kg/m3 |
±5.1
kg/m3 |
±2.6 kg/m3 |
Surface error (1.25mm, 100% Void)
Meas. Depth @ 250 kg/m3
- 212.5mm |
-18.0
kg/m3
|
-18.0
kg/m3
|
-18.0
kg/m3
|
| |
| Calibration |
| Accuracy of Density Standards |
±0.2% |
| Accuracy of Moisture Standards |
±2.0% |
| Calibration Range |
70-170 pcf
(1100-2700 kg/m3) Density
0-40 pcf (0-640 kg/m3) Moisture |
| |
| Radiological |
| Gamma
Source |
8 mCi ±10%
Cs-137 |
Neutron
Source
|
0.060
mCi ±10% Cf-252 or
40 mCi ±10% Am-241:Be
|
| Source
Housing |
Stainless
Steel Encapsulation |
Shielding
|
Tungsten,
lead and cadmium |
Surface
Dose Rates
|
20.5
mrem/hr max., neutron and gamma |
Source Rod
Material
|
Stainless
Steel |
Shipping
Case
|
DOT 7A,
Type A |
Sealed Source Approved for Domestic and
International
Shipments |
Special Form |
| |
| Mechanical |
| Case |
High Impact Plastic
29.5 L x 14 W x 17 T
in. |
| Vibration Test |
0.1 in. (2.5 mm) @ 12.5 hz |
| Drop Test |
300 mm on 25 mm diameter steel ball |
| Operating Temp: |
Ambient: 14 to 158°F (-10 to 70°C)
Surface:
350°F (175°C) |
| Storage Temp. |
-70 to 185°F (-55 to 85°C) |
| Gauge Size (no handles) |
14.8 x 9.1 x 7.2 in.
(376 x 231 x 183 mm) |
| Gauge Height (with handles) |
12": 23.25 in. (591 mm)
8": 19.25 in. (489
mm) |
| Weight |
29 lbs. (13.2 kg) |
| Shipping Weight |
90 lbs. (40.8 kgs) w/case |
| Available Models |
8"
or 12" index rod with 1" or 2" increments
(200 or 300 mm index
rod with 25 or 50 mm increments) |
| |
| Electrical |
| Time
Accuracy and Stability |
0.005%, 0.0002% / °C |
Power
Supply Stability
|
0.01% / °C |
| Stored
Power |
30 watt
hours |
Battery
Recharge Time
|
14-16 hours (automatic
cutoff) |
Charger
|
110/220 V ac, 50-60 Hz or
12-14 V dc |
Readout
|
2 x
16 alpha-numeric liquid crystal display |
| |
Notes:
Gauge
returns to Gauge Ready (power saving mode) after two minutes of
inactivity, except in standard, stat test, drift test, and in
nomograph programs when a 30-minute delay is provided. After 5 hours
of inactivity, gauge performs complete power
shut-down.
Battery packs are fully protected against
overcharge and overdischarge.
Emergency Use - Capable of
operation with D size alkaline batteries. |