Nuclear Gauges & Field Equipment FAQS
Do I have to have a target density (Proctor, Marshall, Voidless) programmed into the gauge in order for it to work?
No. The target value is only used by the gauge to calculate the percent of compaction that has been achieved. The gauge will still give Wet Density, Dry Density, Moisture and Percent Moisture results without the target density entered. The percent compaction can be calculated at a later time if necessary.
Example:
(DD/Proctor) x 100 = %Proctor or (WD/Marshall) x 100 = %Marshall
Return to Top
How will frost (frozen material) affect the gauge readings?
The percent moisture result will be elevated and the dry density read by the nuclear density gauge will be lower if the material contains frost. Therefore, the tests will fail. When the water freezes it expands and takes up a larger volume in the material beneath the gauge. Because water is less dense than the measured material, the density will be lower and the percent moisture will be higher. It is commonly written in engineering specifications that "no fill may be placed over frozen material." In extreme cases, settling could occur if frozen material is covered and thaws at a later time.
Return to Top
My gauge readings do not match my sand cone readings.
Usually they will not. There is a lot of room for operator error when performing a sand cone test. There is really no way to prove which test is more "accurate" because there is no absolute test for soil density. The best way to compare the two test methods is to take at least three 4 minute nuclear gauge measurements at different locations (preferably direct transmission @ 6 or 8 inches) and at least 3 sand cone tests (at the same locations as the gauge readings). Find the difference at all locations and average them.
Return to Top
Should I take a backscatter or direct transmission reading on aggregate base? (usually 4"- 6" in thickness)
Either one would be acceptable. The best thing to do is try one of each. Ideally the direct transmission will give a more representative reading, but it may also disturb the larger aggregate and lower the density. If you try both in the same spot (backscatter test first) and see which gives a better reading you can make the decision for yourself. If the material thickness is over 4", direct transmission is more appropriate in order to get a representative measurement.
Return to Top
What is the prescale factor for my Troxler gauge?
In order to scale the count values to a reasonable number of digits, Troxler devices use prescale factors when performing measurements, standard counts and any other diagnostics count. In other words, the count that a gauge displays is the total number of ionization events measured by the gauge divided by the appropriate prescale factor.
The prescale factor is typically not needed by the gauge operator. However, the ASTM standards D 6938 and D 2950 give a formula which requires the use of the prescale factor to check the stability of the standard counts. The prescale factors are listed below:
For Troxler Models 3401, 3411, 3430, 3430 Plus, 3440, 3440 Plus, and 4300 devices, a prescale of 16 is to be used in the formula when a 4-minute standard count is performed.
For Troxler Models 3450 and 4640 devices, a prescale of 8 is to be used in the formula when a 4-minute standard count is performed.
Return to Top
Can the gauge read the moisture of a concrete slab?
It can read the moisture as a relative reading; in other words it will give an indication of a problem area, but will not give a definite moisture content. There are constituents in concrete that can cause the moisture readings to be in error, but as long as the concrete is homogeneous, the error will be constant. Example: If the slab reads approximately 12% moisture in all areas but one area is approximately 20%, it can be assumed that this is a problem area. This will give an indication of where a core sample should be taken for investigative purposes.
Return to Top
My 3411 gauge is giving the ERROR 30 message.
This message means that the gauge cannot calculate the test results. Usually this is due to the fact that there is no standard count in the memory. Also, this could mean that the depth switch is not correctly set; if the depth switch is set at a value much different than that which is actually being measured, the calculated results will be too large for the gauge to calculate. Try taking a new standard and checking the depth switch before taking a measurement.
Return to Top
Why is my gauge moisture result higher/lower than the oven dry/speedy moisture results?
The oven dry tells the true moisture content by removing all water from the sample. The gauge measures the hydrogen present in the material; which is usually in the form of water. If the material contains naturally occurring hydrogen or bound hydrogen, the gauge will measure the moisture falsely high in many cases. (Some of these materials are: mica, lime, fly ash, cement, organic materials, gypsum, coal, phosphates, etc.) A false low reading can also occur but is less common (causes include: high salt or iron oxide content or boron, lithium or cadmium present). A moisture offset will adjust for this problem.
Return to Top
How often do moisture/density gauges need to be calibrated?
We recommend that the gauges be properly evaluated for accuracy or calibrated every 12 months.
Return to Top
What are the ASTM and AASHTO standards written specifically for moisture and density testing?
- ASTM D 6938 & AASHTO T 310 In-Place Density and Moisture Content of Soil and Soil-Aggregate by Nuclear Methods (Shallow Depth)
- ASTM C 1040 Density of Unhardened and Hardened Concrete In Place by Nuclear Methods
- ASTM D 2950 Density of Bituminous Concrete In Place by Nuclear Methods
Return to Top
My gauge is not charging. What could it be?
For models 3440 and 4640, reset the battery life to 190 hours. Ensure charger is good. Check charger jack to see if it is loose/broken. Possible bad battery pack.
Return to Top
My gauge displays tube error. What's the problem?
Take the gauge to a clean, dry environment and remove the control panel or "scaler". Check for loose hardware inside the gauge that could short the high voltage. Check for moisture inside the gauge and, if moisture is present, remove the scaler and dry overnight with a fan.
Return to Top
Why does my gauge fail the standard count?
Ensure that the gauge is positioned properly. Make sure that those standard counts stored are appropriate by comparing to the factory standard counts reported in the most recent calibration printout. If a standard count has not been performed in more than a month and a new count fails by a small percentage (less than 5%), accept the new count and perform four more. The fifth standard count should pass.
Return to Top
When I try to get my density, I get nothing but +'s. Why?
Obtain the gauge's most recent calibration printout and check that the calibration constants in the memory match those on the printout. Also, verify that the depth strip is functioning correctly. Check for correct standard counts.
Return to Top
Why are my gauge readings off?
Ensure you have a good standard count. Verify you are at the correct depth. Check to make sure no offsets are enabled. Make sure that the handle is clicked into the notch (depth position) properly. Do not pass notch or push up on the handle after positioning it.
Return to Top
Why is my gauge hard to index?
Magnalube is the recommended lubricant. Place a small amount on the source rod and exercise the rod up and down. Check the bottom of the gauge to make sure dirt has not accumulated in the sliding block or base plate area.
Return to Top
Why does my gauge indicate safe position when it is in BS?
You need to calibrate the depth strip. If this doesn't fix the problem, your gauge may need servicing.
Return to Top
My gauge is locked up and there is no keypad response.
Press and hold the OFF button for 15-30 seconds until the gauge turns off. If it does not turn off, remove the scaler and unplug the ribbon cable from the baseboard. Plug the cable back in and turn the gauge on allowing it to go through its 5 minute self-test.
Return to Top
My 3440/4640B is displaying random characters on the display.
Perform memory reset on gauge. 3440 reset / 4640 reset
Return to Top
Do I need a MSDS for my nuclear gauges?
No. Troxler provides a MSDS disclaimer statement for your files.
Return to Top
Which USB devices are compatible with my Model 3440 Plus gauge?
A list of compatible USB devices is available here.
Return to Top