Visit Our Online Cart or call 1-877-876-9537
(For gauges with sources that are not Special Form)
Some older model gauges contain sources which are no longer certified as Special Form. The table below shows the source codes and serial number ranges that are affected and whether the sources can be shipped alternatively as Normal Form in a Type A package or can be shipped under a Special Permit.
Source Code
Affected Source S/N
Nuclide
Ship as Normal Form or Special Permit
15
ALL
Ra-226
Normal Form
16
18
19
25
26
27
33
Cs-137/Am-241
Special Permit
34
35
Cs-137
CC, 40
<4552
45
<2308
Am-241
CA, CAA, 47
<740
48
55
<8132 or between 17978 & 18080
60
63
64
65
70
75
Between 1296 & 1395
Radioactive material which is not certified as Special Form is referred to as “Normal Form.” The standard shipping instructions are based on the assumption that both sources in a gauge are Special Form. When one or both of the sources are Normal Form, the standard instructions are no longer valid.
The following sections explain the modifications necessary to ship a 3400 series gauge in which the Cs-137 is Normal Form and the Am-241 is Special Form.
USA DOT 7A TYPE A RADIOACTIVE MATERIAL, TYPE A PACKAGE, SPECIAL FORM, UN3332, RQ RADIOACTIVE MATERIAL, TYPE A PACKAGE, UN2915